Improvement on vibration measurement performance of laser self-mixing interference by using a pre-feedback mirror open site


Date: Jun, 2018
Improvement on vibration measurement performance of laser self-mixing interference by using a pre-feedback mirror

In the laser self-mixing interference vibration measurement system, the self mixing interference signal is usually weak so that it can be hardly distinguished from the environmental noise. In order to solve this problem, we present a self-mixing interference optical path with a pre-feedback mirror, a pre-feedback mirror is added between the object and the collimator lens, corresponding feedback light enters into the inner cavity of the laser and the interference by the pre-feedback mirror occurs. The pre-feedback system is established after that. The self-mixing interference theoretical model with a pre-feedback based on the F–P model is derived. The theoretical analysis shows that the amplitude of the intensity of the interference signal can be improved by 2–4 times. The influence factors of system are also discussed. The experiment results show that the amplitude of the signal is greatly improved, which agrees with the theoretical analysis.